Take your time. Show your thinking.

  1. 1. In a potential divider circuit connected to a 24 V DC supply, resistor R₁ = 6 Ω and resistor R₂ = 10 Ω are connected in series. Using V_out = (R₂ ÷ (R₁ + R₂)) × V_in, calculate the potential difference across R₂.

    +−R
    V_in = 24 V · R₁ = 6 Ω, R₂ = 10 Ω · V_out = [R₂ ÷ (R₁ + R₂)] × V_in
  2. 2. In a potential divider circuit connected to a 35 V DC supply, resistor R₁ = 16 Ω and resistor R₂ = 24 Ω are connected in series. Using V_out = (R₂ ÷ (R₁ + R₂)) × V_in, calculate the potential difference across R₂. Choose the correct answer: A) 42 V B) 17 V C) 21 V D) 31 V

    +−R
    V_in = 35 V · R₁ = 16 Ω, R₂ = 24 Ω · V_out = [R₂ ÷ (R₁ + R₂)] × V_in
  3. 3. Spot the mistake. In a potential divider circuit connected to a 30 V DC supply, resistor R₁ = 12 Ω and resistor R₂ = 18 Ω are connected in series. Using V_out = (R₂ ÷ (R₁ + R₂)) × V_in, calculate the potential difference across R₂. A learner answered 180 V. What is the correct answer?

    +−R
    V_in = 30 V · R₁ = 12 Ω, R₂ = 18 Ω · V_out = [R₂ ÷ (R₁ + R₂)] × V_in
  4. 4. True or false? In a potential divider circuit connected to a 25 V DC supply, resistor R₁ = 6 Ω and resistor R₂ = 9 Ω are connected in series. Using V_out = (R₂ ÷ (R₁ + R₂)) × V_in, calculate the potential difference across R₂. Someone says the answer is 15 V.

    +−R
    V_in = 25 V · R₁ = 6 Ω, R₂ = 9 Ω · V_out = [R₂ ÷ (R₁ + R₂)] × V_in
  5. 5. In a potential divider circuit connected to a 20 V DC supply, resistor R₁ = 14 Ω and resistor R₂ = 21 Ω are connected in series. Using V_out = (R₂ ÷ (R₁ + R₂)) × V_in, calculate the potential difference across R₂. Choose the correct answer: A) 24 V B) 12 V C) 10 V D) 22 V

    +−R
    V_in = 20 V · R₁ = 14 Ω, R₂ = 21 Ω · V_out = [R₂ ÷ (R₁ + R₂)] × V_in
  6. 6. Spot the mistake. In a potential divider circuit connected to a 28 V DC supply, resistor R₁ = 2 Ω and resistor R₂ = 6 Ω are connected in series. Using V_out = (R₂ ÷ (R₁ + R₂)) × V_in, calculate the potential difference across R₂. A learner answered 210 V. What is the correct answer?

    +−R
    V_in = 28 V · R₁ = 2 Ω, R₂ = 6 Ω · V_out = [R₂ ÷ (R₁ + R₂)] × V_in
  7. 7. True or false? In a potential divider circuit connected to a 30 V DC supply, resistor R₁ = 2 Ω and resistor R₂ = 4 Ω are connected in series. Using V_out = (R₂ ÷ (R₁ + R₂)) × V_in, calculate the potential difference across R₂. Someone says the answer is 20 V.

    +−R
    V_in = 30 V · R₁ = 2 Ω, R₂ = 4 Ω · V_out = [R₂ ÷ (R₁ + R₂)] × V_in
  8. 8. In a potential divider circuit connected to a 30 V DC supply, resistor R₁ = 10 Ω and resistor R₂ = 15 Ω are connected in series. Using V_out = (R₂ ÷ (R₁ + R₂)) × V_in, calculate the potential difference across R₂.

    +−R
    V_in = 30 V · R₁ = 10 Ω, R₂ = 15 Ω · V_out = [R₂ ÷ (R₁ + R₂)] × V_in
  9. 9. Spot the mistake. In a potential divider circuit connected to a 27 V DC supply, resistor R₁ = 9 Ω and resistor R₂ = 18 Ω are connected in series. Using V_out = (R₂ ÷ (R₁ + R₂)) × V_in, calculate the potential difference across R₂. A learner answered 20 V. What is the correct answer?

    +−R
    V_in = 27 V · R₁ = 9 Ω, R₂ = 18 Ω · V_out = [R₂ ÷ (R₁ + R₂)] × V_in
  10. 10. True or false? In a potential divider circuit connected to a 21 V DC supply, resistor R₁ = 11 Ω and resistor R₂ = 22 Ω are connected in series. Using V_out = (R₂ ÷ (R₁ + R₂)) × V_in, calculate the potential difference across R₂. Someone says the answer is 17 V.

    +−R
    V_in = 21 V · R₁ = 11 Ω, R₂ = 22 Ω · V_out = [R₂ ÷ (R₁ + R₂)] × V_in
  11. 11. In a potential divider circuit connected to a 28 V DC supply, resistor R₁ = 6 Ω and resistor R₂ = 15 Ω are connected in series. Using V_out = (R₂ ÷ (R₁ + R₂)) × V_in, calculate the potential difference across R₂.

    +−R
    V_in = 28 V · R₁ = 6 Ω, R₂ = 15 Ω · V_out = [R₂ ÷ (R₁ + R₂)] × V_in
  12. 12. In a potential divider circuit connected to a 10 V DC supply, resistor R₁ = 6 Ω and resistor R₂ = 9 Ω are connected in series. Using V_out = (R₂ ÷ (R₁ + R₂)) × V_in, calculate the potential difference across R₂. Choose the correct answer: A) 7 V B) 12 V C) 4 V D) 6 V

    +−R
    V_in = 10 V · R₁ = 6 Ω, R₂ = 9 Ω · V_out = [R₂ ÷ (R₁ + R₂)] × V_in
12 questions · Seed 150 · Age guidance, not curriculum certification
View the answer key
Worksheet StudioAnswer key · Ages 13-15

Potential divider circuits

Answers and reasoning. Review before teaching.

  1. 1. In a potential divider circuit connected to a 24 V DC supply, resistor R₁ = 6 Ω and resistor R₂ = 10 Ω are connected in series. Using V_out = (R₂ ÷ (R₁ + R₂)) × V_in, calculate the potential difference across R₂.

    15 V

    Total resistance R₁ + R₂ = 6 + 10 = 16 Ω. Potential difference across R₂ is V_out = (10 ÷ 16) × 24 V = 15 V.

  2. 2. In a potential divider circuit connected to a 35 V DC supply, resistor R₁ = 16 Ω and resistor R₂ = 24 Ω are connected in series. Using V_out = (R₂ ÷ (R₁ + R₂)) × V_in, calculate the potential difference across R₂. Choose the correct answer: A) 42 V B) 17 V C) 21 V D) 31 V

    C) 21 V

    Total resistance R₁ + R₂ = 16 + 24 = 40 Ω. Potential difference across R₂ is V_out = (24 ÷ 40) × 35 V = 21 V.

  3. 3. Spot the mistake. In a potential divider circuit connected to a 30 V DC supply, resistor R₁ = 12 Ω and resistor R₂ = 18 Ω are connected in series. Using V_out = (R₂ ÷ (R₁ + R₂)) × V_in, calculate the potential difference across R₂. A learner answered 180 V. What is the correct answer?

    18 V

    Total resistance R₁ + R₂ = 12 + 18 = 30 Ω. Potential difference across R₂ is V_out = (18 ÷ 30) × 30 V = 18 V.

  4. 4. True or false? In a potential divider circuit connected to a 25 V DC supply, resistor R₁ = 6 Ω and resistor R₂ = 9 Ω are connected in series. Using V_out = (R₂ ÷ (R₁ + R₂)) × V_in, calculate the potential difference across R₂. Someone says the answer is 15 V.

    True

    Total resistance R₁ + R₂ = 6 + 9 = 15 Ω. Potential difference across R₂ is V_out = (9 ÷ 15) × 25 V = 15 V.

  5. 5. In a potential divider circuit connected to a 20 V DC supply, resistor R₁ = 14 Ω and resistor R₂ = 21 Ω are connected in series. Using V_out = (R₂ ÷ (R₁ + R₂)) × V_in, calculate the potential difference across R₂. Choose the correct answer: A) 24 V B) 12 V C) 10 V D) 22 V

    B) 12 V

    Total resistance R₁ + R₂ = 14 + 21 = 35 Ω. Potential difference across R₂ is V_out = (21 ÷ 35) × 20 V = 12 V.

  6. 6. Spot the mistake. In a potential divider circuit connected to a 28 V DC supply, resistor R₁ = 2 Ω and resistor R₂ = 6 Ω are connected in series. Using V_out = (R₂ ÷ (R₁ + R₂)) × V_in, calculate the potential difference across R₂. A learner answered 210 V. What is the correct answer?

    21 V

    Total resistance R₁ + R₂ = 2 + 6 = 8 Ω. Potential difference across R₂ is V_out = (6 ÷ 8) × 28 V = 21 V.

  7. 7. True or false? In a potential divider circuit connected to a 30 V DC supply, resistor R₁ = 2 Ω and resistor R₂ = 4 Ω are connected in series. Using V_out = (R₂ ÷ (R₁ + R₂)) × V_in, calculate the potential difference across R₂. Someone says the answer is 20 V.

    True

    Total resistance R₁ + R₂ = 2 + 4 = 6 Ω. Potential difference across R₂ is V_out = (4 ÷ 6) × 30 V = 20 V.

  8. 8. In a potential divider circuit connected to a 30 V DC supply, resistor R₁ = 10 Ω and resistor R₂ = 15 Ω are connected in series. Using V_out = (R₂ ÷ (R₁ + R₂)) × V_in, calculate the potential difference across R₂.

    18 V

    Total resistance R₁ + R₂ = 10 + 15 = 25 Ω. Potential difference across R₂ is V_out = (15 ÷ 25) × 30 V = 18 V.

  9. 9. Spot the mistake. In a potential divider circuit connected to a 27 V DC supply, resistor R₁ = 9 Ω and resistor R₂ = 18 Ω are connected in series. Using V_out = (R₂ ÷ (R₁ + R₂)) × V_in, calculate the potential difference across R₂. A learner answered 20 V. What is the correct answer?

    18 V

    Total resistance R₁ + R₂ = 9 + 18 = 27 Ω. Potential difference across R₂ is V_out = (18 ÷ 27) × 27 V = 18 V.

  10. 10. True or false? In a potential divider circuit connected to a 21 V DC supply, resistor R₁ = 11 Ω and resistor R₂ = 22 Ω are connected in series. Using V_out = (R₂ ÷ (R₁ + R₂)) × V_in, calculate the potential difference across R₂. Someone says the answer is 17 V.

    False. The correct answer is 14 V.

    Total resistance R₁ + R₂ = 11 + 22 = 33 Ω. Potential difference across R₂ is V_out = (22 ÷ 33) × 21 V = 14 V.

  11. 11. In a potential divider circuit connected to a 28 V DC supply, resistor R₁ = 6 Ω and resistor R₂ = 15 Ω are connected in series. Using V_out = (R₂ ÷ (R₁ + R₂)) × V_in, calculate the potential difference across R₂.

    20 V

    Total resistance R₁ + R₂ = 6 + 15 = 21 Ω. Potential difference across R₂ is V_out = (15 ÷ 21) × 28 V = 20 V.

  12. 12. In a potential divider circuit connected to a 10 V DC supply, resistor R₁ = 6 Ω and resistor R₂ = 9 Ω are connected in series. Using V_out = (R₂ ÷ (R₁ + R₂)) × V_in, calculate the potential difference across R₂. Choose the correct answer: A) 7 V B) 12 V C) 4 V D) 6 V

    D) 6 V

    Total resistance R₁ + R₂ = 6 + 9 = 15 Ω. Potential difference across R₂ is V_out = (9 ÷ 15) × 10 V = 6 V.

12 questions · Seed 150 · Age guidance, not curriculum certification